File 1 of 6
Clothes dryers
No heat, two cycles for one load, a squeal from the drum. Airflow at the vent hood gets checked on every dryer call.
Clothes dryers in BurlingtonBurlington · gas and electric dryers
Dryer repair in Burlington, gas or electric
Most Burlington dryers that stop heating have a simple reason, often lint in a long vent run. We test the whole path from heater to outside wall, carry the usual fuses, igniters and elements, and price the repair in writing before starting.

Burlington's dryers split roughly along housing lines. Apartment buildings and many townhomes rely on electric machines, often stacked above a washer in a closet, with a vent duct that snakes through a wall or ceiling before it reaches open air. Older single-family homes and some newer ones on the edge of town have natural gas hookups, and on the farms around Bow and Edison you will find both. The failures overlap more than people expect: whichever fuel heats it, a dryer that cannot breathe will overheat, cut out and eventually blow a thermal fuse.
So the first thing our technicians do on a no-heat call is check the airflow, from the lint screen through the transition duct to the hood on the outside wall. Then we test the heating side: element, thermal fuse, cycling and high-limit thermostats on electric models; igniter, flame sensor and gas valve coils on gas ones. We carry those parts for Whirlpool, Maytag, GE, LG, Samsung and Kenmore dryers, which covers most of what we meet in Burlington laundry rooms. When the dryer shares a closet with the washer, we look at both hookups while the panels are off, since a weeping washer valve beside a dryer is a common source of rust and shorted wiring.
You noticeDrum turns but the clothes stay cold
Usual sourceBlown thermal fuse or open heating element on electric; failed igniter or valve coil on gas
Our repairTest the heating circuit, replace the failed part and find out what made it fail
You noticeA load needs two or three cycles to dry
Usual sourceLint-packed vent run, crushed transition duct or a stuck hood flap
Our repairMeasure the airflow, clear the vent path and straighten or replace the transition duct
You noticeDryer will not start at all
Usual sourceDoor switch, thermal fuse, start switch or a tripped breaker
Our repairCheck the breaker with you first, then test the start circuit part by part
You noticeThumping or squealing while the drum turns
Usual sourceWorn drum rollers, idler pulley or drive belt
Our repairReplace the worn rollers, belt or pulley and check the drum glides
You noticeGas dryer igniter glows, then nothing lights
Usual sourceGas valve coils that quit once warm
Our repairBench-test both coils and fit a matched pair
You noticeBurning smell, or a cabinet hot to the touch
Usual sourceLint buildup around the heater or a failed cycling thermostat
Our repairShut the dryer off, clean the housing and test every safety thermostat
Close to three in ten Burlington homes are in buildings of five or more units, and in many of them the dryer vent travels a long way before it reaches an outside wall, sometimes with a couple of bends and a roof or soffit exit. That design works while the duct is clean. As lint builds, the dryer runs hotter and longer, the high-limit starts cycling the heat, and eventually the thermal fuse opens. Replacing the fuse alone just resets the clock, so we trace the vent as far as we can reach and tell you if the building's duct needs cleaning by whoever maintains it. We also look at the hood outside: a flap painted shut or a cage packed with lint stops airflow just as surely as a clogged duct.
Gas dryers that stood in December 2025 floodwater need extra caution. Water and silt in the burner assembly, the gas valve and the flame sensor wiring can leave a dryer that lights unreliably or not at all. We do not relight a gas dryer whose controls were submerged without testing them and replacing what the water reached, and if the damage is broad we will recommend retiring it. Electric dryers fare a little better, though their motors and timers sit low enough to have been soaked in most flooded laundry rooms.
A gas odor around a dryer changes the order of things. Get everyone out first, without flipping switches or pulling plugs, and phone 911 from the yard or a neighbor's house. When the gas side has been secured, book us and we will find out whether the dryer was the source.

You won't find prices here: a thermal fuse or valve coil for one dryer can be priced far apart from one make to the next, so we meter yours first and write one price, and the work waits for your approval. Your visit fee comes off the repair once you give the go-ahead.
Tap a tab or let the folder turn on its own.

File 1 of 6
No heat, two cycles for one load, a squeal from the drum. Airflow at the vent hood gets checked on every dryer call.
Clothes dryers in Burlington
File 2 of 6
Warm shelves, frost across the rear panel, a garage freezer that quits in a cold snap: defrost parts, fans and relays get tested before we name a fix.
Refrigerators and freezers in Burlington
File 3 of 6
A drum that keeps its water, a lid lock stuck shut, a spin that rocks the floor: front-loaders, top-loaders and stacked towers alike.
Washing machines in Burlington
File 4 of 6
An oven element gone dark, burners clicking with no flame, a glass-top burner that will not shut off, on gas and electric ranges alike.
Ranges, ovens and cooktops in Burlington
File 5 of 6
Grey water left behind, glasses turning cloudy, a drip by the toe kick, a panel that blinks and sulks.
Dishwashers in Burlington
File 6 of 6
Empty bins, thin hollow cubes, a fill line frozen in an outflow week: valve, line and module, tested in order.
Ice makers in BurlingtonDryers are simple machines, and most of what goes wrong with them is affordable to fix: fuses, thermostats, elements, igniters, valve coils, belts, rollers and switches. A dryer with a sound drum and a solid cabinet can keep going for many more years after one of those repairs, which is why we rarely recommend replacing one for a heating fault alone. The cases where we lean the other way are a cracked or rusted-through drum, a motor that has seized after years of overheating behind a clogged vent, or a gas dryer that sat in floodwater long enough to soak its valve and burner. In rentals, landlords sometimes weigh a dryer repair against buying a matching pair; we will give you the repair figure in writing so that comparison is easy to make, and we will point out the vent problem that caused the failure so a new dryer does not inherit it.
Only once it has been tested. Floodwater can leave silt in the burner and corrosion on the gas valve coils and wiring, and a gas dryer with damaged controls should not be relit on hope. We test the valve, igniter, flame sensor and wiring, replace what the water reached if that makes sense, and recommend replacement when the damage runs deeper.
Getting everyone out of the house, without switching lights or appliances on or off. Then call 911 from outside. They will make the gas line safe. After that, book a visit and we will find out whether a fitting, the valve or the dryer itself is the source and what it will take to fix.
We clear the parts of the vent we can reach from the dryer, including the transition duct and the first stretch of the run, and we test the airflow at the exit. Long shared ducts inside walls or through the roof belong to the building, so we note on the estimate if the main run needs cleaning and the owner can arrange it.
Yes, both. Out on the farms, dryers often share a utility room with a chest freezer or a second fridge, and some run long vents through an exterior wall to the yard. Bow and Edison are on our regular routes along Chuckanut Drive and Bow Hill Road, and the call-out fee comes off the repair total when you go ahead.
A thermal fuse opens when the exhaust gets too hot, and it is almost always telling you about airflow. A blocked lint screen housing, a crushed duct behind the dryer or a long, dirty vent run lets the heat build up. We replace the fuse, then find and fix the restriction so the new one does not blow next month.
Set up the visit
Ring (360) 525-9166 or book online to schedule a Burlington dryer repair.
Dryer venting
Long dryer vent runs, crushed hoses and rooftop exits in condos and older homes: how they burn out thermal fuses, slow drying and raise fire risk.
Book a visit
Leave a few details and a dispatcher rings you back to agree on an arrival window. Someone picks up all week, and a request sent before mid-morning has the likeliest shot at a visit the same day.
Prefer to talk? (360) 525-9166 · Calls daily 8–7
State records
Both credentials are public state records. Tap a card for details, or look the numbers up yourself on L&I Verify.
Check our licenses yourself